Customization: | Available |
---|---|
Application: | Communication, Sensor, Medicine, Probe |
Type: | Single-mode Fiber |
Still deciding? Get samples of US$ 0.1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Test Type | Test Item | Target | Reference | |
Differential Impedence | 100+/ -10ohm (Rise time of 50 ps (20 %- 80 %)) | IEEE Std.802.3ba | ||
Electrical Characteristics | Differential Mode RL | Frequency(GHz) 0.1-1.0 1.0-4.1 |
SDD11 & SDD22(max) -10 -(12-2*sqrt(f)) |
Per table 10 of 1B Cable MOL.v 0.68 |
Differential IL | Frequency 100MHz 200MHz 625MHz 1250MHz 1875MHz 2500MHz |
SDD21(min) -8 -8 -8.5 -12.1 -14.7 -17 |
Ref table 43 of Infiniband Architecture Spec, V2 | |
NEXT | ≥26dB @ 10MHz to 5.0GHz | / | ||
Intra-Pair Skew | ≤100 ps(TDT Method) Rise time of 35 ps | (20 %- 80 %) | ||
Intra-Pair Skew | ≤400 ps(TDT Method) Rise time of 35 ps | (20%~80 %) | ||
Environmental Characteristics |
Operating Temperature | -40~85°C | Cable operating temp. range | |
Thermal Shock | No evidence of physical damage | EIA-364-32 Test | ||
Cyclic Temp. & Humidity | No evidence of physical damage | EIA-364-31 Method III,Test Cond A | ||
Salt spray | 48 hours salt spraying after shell corrosive area less than 5% | EIA-364-26 | ||
Temperature Life | Performance meets the specification requirement | EIA-364-17, Method A, Test Cond 3 at 105°±2°C | ||
Mechanical Characteristics |
MechanicaI Vibration | Performance meets the specification requirement | EIA-364-28E.11 TC-VII, Test Cond. D 15minutes in X,Y,Z axis. | |
Cable Flex | Performance meets the specification requirement | EIA-444-1B | ||
Mechanical Shock | Performance meets the specification requirement | EIA-364-27B, TG-G. 3 times in 6 directions, 100g, 6ms | ||
Cable plug Insertion | 40N Max. | Per QSFP MSA Rev 1.0 | ||
Cable plug extraction | 30N Max. | Per QSFP MSA Rev 1.0. | ||
Latch retention force | 50N Min. No evidence of physical damage | EIA-364-13 | ||
Durability | 50 Time. No evidence of physical damage | EIA-364-09; perform plug&unplug cycles |
Parameter | Symbol | Min | Max | Unit |
Maximum Supply Voltage | Vcc | 0 | 3.6 | V |
Storage Temperature | Ts | -40 | 85 | °C |
Relative Humidity | RH | 5 | 95 | % |
Parameter | Symbol | Min | Typical | Max | Unit |
Operating Case Temperature | Standard Tc | 0 | 25 | 70 | °C |
Storage Temperature | Ts | 0 | 70 | °C | |
Relative Humidity | RH | 5 | 95 | % | |
Data Rate | 40 | Gbps | |||
Power Dissipation | PD | 0.02 | W |