FTTH optic Splitter Fiber Optical Coupler Ratio Splitter 50:50~99:1 FBT Coupler
The single mode standard coupler features low excess loss, high stability and reliability. It is built by asymmetric coupling technique. The operating bandwidth of this normal coupler is expanding to ±40nm, and the ultra broadband coupler is expanding to ±80nm. The DWC has the same coupling ratio on both 1310nm and 1550nm communication windows, and with low excess loss and low PDL. DWC are widely used for communication systems, fiber optic cable coupler CATV, and FTTH.
SPECIFICATION OF FBT SPLITTER
Table(1)
| Coupling Ratio | Insertion Loss(dB) | |
| P Grade | S Grade | |
| 50/50 | ≤3.4 | ≤3.6 |
| 45/55 | ≤3.7/2.7 | ≤3.8/2.9 |
| 40/60 | ≤4.4/2.6 | ≤4.7/2.8 |
| 35/65 | ≤4.8/2.0 | ≤4.9/2.10 |
| 30/70 | ≤5.7/1.9 | ≤6.0/2.0 |
| 25/75 | ≤6.9/1.3 | ≤6.5/1.4 |
| 20/80 | ≤7.6/1.2 | ≤8.0/1.3 |
| 15/85 | ≤8.6/0.7 | ≤8.9/0.88 |
| 10/90 | ≤11.0/0.65 | ≤11.5/0.8 |
| 5/95 | ≤14.2/0.4 | ≤14.8/0.5 |
| 2/98 | ≤18.5/0.25 | ≤19.0/0.35 |
| 1/99 | ≤21.5/0.2 | ≤22.0/0.3 |
| Excess Loss(Typ.)(dB) | ≤0.1 | |
| PDL(Max.)(dB) | ≤0.1 | |
| Operating Wavelength(nm) | 1310±40, 1550±40,1310/1550±40,1310/1550/1490±40 or custom wavelength | |
| Directivity(dB) | ≥55 | |
| Return Loss(dB) | ≥50 | |
| Port Configuration | 1×2 or 2×2 | |
| Parameter | Specification | ||||||||
| Operating Wavelength(nm) | 1310±40, 1550±40,1490±10 | ||||||||
| Fiber Type | SMF | ||||||||
| (1×N)(2×N) | N=3 | N=4 | N=5 | N=6 | N=8 | N=10 | N=16 | N=24 | N=32 |
| IL(MAX)(dB) | 5.4 | 6.9 | 8.1 | 8.9 | 10.3 | 11.5 | 13.8 | 15.6 | 17.2 |
| Uniformity(dB) | 0.5 | 0.7 | 1.1 | 1.3 | 1.5 | 1.7 | 1.8 | 2 | 2.2 |
| PDL(dB) | ≤0.20 | ≤0.20 | ≤0.30 | ≤0.30 | ≤0.30 | ≤0.40 | ≤0.40 | ≤0.50 | ≤0.50 |
| Return Loss(dB) | ≥55 | ||||||||
| Directivity(dB) | ≥50 | ||||||||
Note:All the data above does not include connectors.