Customization: | Available |
---|---|
Application: | Communication, Sensor, Medicine, Probe |
Type: | Single-mode Fiber |
Still deciding? Get samples of US$ 0.1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Test Type | Test Item | Target | Reference |
Electrical Characteristics | Differential Mode RL(SDDII) | 0.01<f<4.1 ; < -12+2*SQRT(f ) 4. 1<f<11. 1 ; <-6.3+13*log10(f/5.5) Where f is in GHz Measurements units: dB |
SFF 8431 |
Common mode return loss (SCCII) | 0.01<f<2.5 ; <-7+1.6(f ) 2.5<f<11.1 ; <-3 Where f is in GHz Measurements units: dB |
SFF 8431 | |
NEXT | <-26dB from 1MHz to 11GHz | / | |
Cable assembly Impedence | 100+/ -100hm Rise time of 30 ps (20 %- 80 %) |
(20%~80 %) | |
Insertion Loss Deviation | -1dB≤ILD≤1dB 300KHz≤f≤6GHz |
/ | |
Environmental Characteristics |
Operating Temperature | -40~85°C | Cable operating temp. range |
Thermal Shock | Electrical performance meet the specification requirement | EIA-364-32D. Method A. TC-1. -55 10 85C,100 cycles, 15 min, dwells | |
Cyclic Temp. & Humidity | Electrical performance meet the specification requirement | EIA-364-31 Method III,Test Cond A | |
Salt spray | 48 hours salt spraying after shell corrosive area less than 5% | EIA-364-26 | |
Temperature Life | Performance meets the specification requirement | EIA-364-17B w/ RH, Damp heat 85C at 85% RH for 500 hours | |
Mechanical Characteristics |
MechanicaI Vibration | Performance meets the specification requirement | EIA-364-28E.11 TC-VII, Test Cond. D 15minutes in X,Y,Z axis. |
Cable Plug Retention in Cage | 90N Min. | No functional damage to cable plug below 90N. Per SFF-8432 Rev 5.0 | |
Cable Retention in Plug | 90N Min. | EIA-455-6B | |
Mechanical Shock | Performance meets the specification requirement | Clamp and Shock per EIA-364-27B, TC-G, 3times in 6directions, 100g, 6ms |
Parameter | Symbol | Min | Max | Unit |
Maximum Supply Voltage | Vcc | 0 | 3.6 | V |
Storage Temperature | Ts | -40 | 85 | °C |
Relative Humidity | RH | 5 | 95 | % |
Parameter | Symbol | Min | Typical | Max | Unit |
Operating Case Temperature | Standard Tc | 0 | 25 | 70 | °C |
Storage Temperature | Ts | -40 | 85 | °C | |
Power Supply Voltage | Vcc | 3.13 | 3.30 | 3.47 | V |
Power Dissipation | PD | 0.5 | W | ||
Relative Humidity | RH | 5 | 95 | % | |
Data Rate | 10.5 | Gbps |